網(wǎng)站基本參數(shù)配置中設(shè)置站點(diǎn)描述">

国产美女一级a爱视频免费看_日韩久久无码精品午夜褔利_在线播放又黄又硬又爽_免费人成网站www_强奷漂亮的女邻居中文字幕_韩国三级a视频在线观看_一本久久精品无码av三级_女人18水真多a级毛片免费_国产精品永久免费播放_狼人香蕉香蕉在线视频播放

    
CH  |  EN        
Home > Product System > solution > Test Equipments > Driver controller test bench
New R&D productsHi-tech introduce productsRail transit equipments4S Smart ServiceAerospace products
Driver controller test bench

Driver controller test bench

1. The Use

It is suitable for the test after the maintenance of the subway vehicle driver controller. It can test the logic of the cam switch action of the controller during the operation of the main handle. It can automatically record the logic of the action, the state of the switch, the voltage and current of the input and output, etc. And contact state and contact resistance test and insulation resistance test, automatically generate reports and display visually on the computer display (detected output voltage is expressed in the form of linear graph), can be compared with standard data, showing analysis results , can perform multiple consecutive tests and compare and analyze the results.

2. Main Characteristics

1) All reports are in standard Excel format in Windows 7 under Windows 7; capable of printing (with printer).

2) The equipment has a safe and good protection function, which can safely and effectively protect various faults such as short circuit, open circuit, over voltage and over current during operation, and can automatically recover after the fault disappears;

3) All input and output interface lines of the equipment must comply with national standards (including color, materials, processes, etc.), and when connected to the equipment under test, use safe and reliable, easy to use aviation plug connection method (using international standards or national standards).

3. Main technical parameters

1

Controller potentiometer output voltage

DC 0-10V; error <0.2%

2

Contact resistance measurement range

0 to 5KΩ, error <1mΩ;

3

Insulation resistance measurement range

0 to 200 MΩ, error <10 Ω

4

Detection accuracy

0.1% Fs or more

5

Instrument accuracy level

Above 0.2

6

Effective stroke

≥48 road

7

Analog input interface

≥3 road

4. Industrial computer system configuration requirements:

1

Hard drive capacity

≥500G

2

Memory

≥4G

3

CPU

Core I5 and above

4

LCD screen

≥19 inches

5

USB interface Qty

≥3

5. Equipment photo